aiotestking uk

NS0-520 Exam Questions - Online Test


NS0-520 Premium VCE File

Learn More 100% Pass Guarantee - Dumps Verified - Instant Download
150 Lectures, 20 Hours

Our pass rate is high to 98.9% and the similarity percentage between our NS0-520 study guide and real exam is 90% based on our seven-year educating experience. Do you want achievements in the Network-Appliance NS0-520 exam in just one try? I am currently studying for the Network-Appliance NS0-520 exam. Latest Network-Appliance NS0-520 Test exam practice questions and answers, Try Network-Appliance NS0-520 Brain Dumps First.

Check NS0-520 free dumps before getting the full version:

NEW QUESTION 1

A customer wants to deploy NVMe/FC along with an existing FC SAN fabric using ONTAP 9.8. In this scenario, which two actions are correct? (choose two)

  • A. Use existing zoning on fabric switches
  • B. Enable NVMe/FC on the existing FC SVM
  • C. Upgrade your FC switches from 16GB to 32GB
  • D. Create new zoning on fabric switches

Answer: AB

Explanation:
Because NVMe/FC simply swaps command sets from SCSI to NVMe, it is an easy transition to make.
NVMe/FC uses the same FC transport and therefore the same hardware from the host, through the
switch and all the way to the NVMe/FC target port on the storage array. Thus, NVMe/FC implementations can use existing FC infrastructure, including HBAs, switches, zones, targets, and cabling.
You can find more information on this link: https://www.netapp.com/de/media/10681-tr4684.pdf

NEW QUESTION 2

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, which type of zoning should be used?

  • A. a WWPN with a single initiator and multiple targets
  • B. a WWPN with a single initiator and a single target
  • C. a WWNN with a single initiator and multiple targets
  • D. a WWNN with a single Initiator and a single target

Answer: B

NEW QUESTION 3

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, what is the total amount of space that is guaranteed for the LUNs in the
/vo1/vo1_sanlunsiprod_03 volume?

  • A. 0 GB
  • B. 300 GB
  • C. 600 GB
  • D. 2600 GB

Answer: A

NEW QUESTION 4

You upgraded your Linux hosts to SUSE Enterprise Linux 15. In this scenario, which two actions should you perform before you test asymmetric namespace access (ANA)? (Choose two)

  • A. Verify if the NVMe service has started
  • B. Verify if the LUNs and namespaces are in the same volume.
  • C. Verify if the version of Netapp ONTAP software is 9.5 or later
  • D. Verify if there is only one LIF in the SVM

Answer: AC

Explanation:
ONTAP 9.5 Introduces ANA
Diagram Description automatically generated
NS0-520 dumps exhibit
https://www.netapp.com/de/media/10681-tr4684.pdf

NEW QUESTION 5

Exhibit.
NS0-520 dumps exhibit
An administrator has an AFF A200 HA pair.
Referring to the exhibit, how many 10 Gbps connections would the customer have on a single node for SAN host connectivity?

  • A. 4
  • B. 6
  • C. 7
  • D. 2

Answer: A

NEW QUESTION 6

An administrator enabled the FCP protocol on an SVM and created a boot LUN for a Windows Server 2019 server host. The host is attached using multiple paths to the storage SVM. After correctly adding
the LUN to the igroup and setting its LUN ID to 1, the host is unable to boot using the installed FC HBA.

  • A. The LUN ID must be set to 0
  • B. The LUN ID must be set to 255
  • C. During the boot process, using FCP is not supported by Netapp
  • D. During the boot process, using FCP is not supported by Microsoft

Answer: A

Explanation:
Create the LUN that you want to use as a boot device, and map it to the igroup as LUN ID 0 You can find more information on this link:
https://library.netapp.com/ecmdocs/ECMP1656701/html/GUID-76BFD6AC-BC2A-419A-9DD3-D98423B2B6

NEW QUESTION 7

A storage administrator created a LUN using two ports on a storage system. Later, additional LUNs were added to the same node as the original LUN. After a while, the performance of the original LUN dropped beyond an acceptable level.
What would you advise to remedy the Issue?

  • A. Add an additional switch between the hosts and cluster.
  • B. Add new LIFs on unused ports.
  • C. Add new LIFs on the used ports.
  • D. Reduce the queue depth on the used ports.

Answer: B

NEW QUESTION 8

The ESX host reports inconsistent performance for iSCSI-based connectivity. In this scenario, what would cause this problem?

  • A. The host and storage are connected to different switches.
  • B. The flow control was disabled on the storage.
  • C. The hardware initiators were used instead of software.
  • D. The flow control is enabled on the storage.

Answer: B

NEW QUESTION 9

You are testing FCP paths failures on a 2-node Netapp AFF All SAN Array and verify that persistent ports are correctly enabled. Before testing, a host sees four optimized paths to a LUN. You perform a
node takeover and re-check the host.
Which statement is true after the node takeover?

  • A. The host sees four optimized paths to the LUN
  • B. The host sees two non-optimized paths and two dead paths to the LUN
  • C. The host sees two optimized paths and two non-optimized paths to the LUN
  • D. The host sees two optimized paths and two dead paths to the LUN

Answer: A

Explanation:
Support for persistent ports
Beginning in ONTAP 9.8, persistent ports are enabled by default on All SAN Arrays (ASAs) that are configured to use the FC protocol. Persistent ports are only available for FC and require zone
membership identified by World Wide Port Name (WWPN).
Persistent ports reduce the impact of takeovers by creating a shadow LIF on the corresponding physical port of the HA partner. When a node is taken over, the shadow LIF on the partner node assumes the
identity of the original LIF, including the WWPNe. Before the status of path to the taken over node is changed to faulty, the shadow LIF appears as an Active/Optimized path to the host MPIO stack, and I/O is
shifted. This reduces I/O disruption because the host always sees the same number of paths to the target, even during storage failover operations.
You can find more information on this link:
https://docs.netapp.com/allsan/index.jsp?topic=%2Fcom.netapp.doc.dot-asa-config%2FGUID-646B3CFD-9E00

NEW QUESTION 10

An administrator is adding new hosts to a vSphere cluster. The cluster uses the FC protocol to connect to a NetApp cluster. The administrator wants to configure the multipathing for the ESXi host.
Which NetApp tool should be used to accomplish this task?

  • A. OnCommand System Manager (OCSM)
  • B. Host Utilities
  • C. SnapCenter plug-in
  • D. NetApp Virtual Storage Console (VSC)

Answer: D

Explanation:
Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1547465

NEW QUESTION 11

What is the supported NVMe OS multipathing stack for VMware ESXi?

  • A. dm-multipath
  • B. MPIO
  • C. NMP
  • D. PVlinks

Answer: C

Explanation:
Reference: https://www.netapp.com/us/media/tr-4684.pdf (18)

NEW QUESTION 12

A customer has multiple host applications that require FC block storage. You need to gather and validate the customer’s requirements for a supported NetApp solution.
Which two tools would be used to accomplish this task? (Choose two.)

  • A. Interoperability Matrix Tool (IMT)
  • B. OneCollect
  • C. Config Advisor
  • D. Hardware Universe (HWU)

Answer: AD

Explanation:
Reference: https://www.netapp.com/us/technology/interop.aspx

NEW QUESTION 13

You currently have a FAS8200 with ONTAP 9.5. You want to expand the front end FC I/O capabilities. However, you are unsure which target adapters are supported.
What would you use to confirm which adapters are supported with your current configuration?

  • A. Hardware Universe (HWU)
  • B. Upgrade Advisor
  • C. OneCollect
  • D. Interoperability Matrix Tool (IMT)

Answer: A

NEW QUESTION 14

You create a 20 GB LUN in a newly created 100 GB FlexVol volume. You then write 5 GB of data to the LUN. You have space reservation disabled on the LUN.
In this scenario, how much space do you have left on the volume?

  • A. 95 GB
  • B. 80 GB
  • C. 75 GB
  • D. 85 GB

Answer: A

Explanation:
Reference: https://library.netapp.com/ecmdocs/ECMP1368017/html/GUID-0E0B085C-5A42-43F3-9CCD- 4FD699BA6C89.html

NEW QUESTION 15

NS0-520 dumps exhibit
Which two storage efficiencies have been enabled on the NVMe namespace that is shown in the exhibit? (Choose two.)

  • A. deduplication
  • B. compaction
  • C. compression
  • D. thin provisioning

Answer: B

NEW QUESTION 16

What are two examples of supported NetApp FC configurations? (Choose two.)

  • A. a single NetApp node directly connected to a single host
  • B. a single switched environment with a NetApp node connected to only one host
  • C. a dual switched environment with a NetApp node connected to multiple hosts
  • D. a single NetApp node directly connected to multiple hosts

Answer: BC

NEW QUESTION 17
......

Recommend!! Get the Full NS0-520 dumps in VCE and PDF From Thedumpscentre.com, Welcome to Download: https://www.thedumpscentre.com/NS0-520-dumps/ (New 234 Q&As Version)