aiotestking uk

DEE-1421 Exam Questions - Online Test


DEE-1421 Premium VCE File

Learn More 100% Pass Guarantee - Dumps Verified - Instant Download
150 Lectures, 20 Hours

Proper study guides for Leading EMC Expert - Isilon Solutions certified begins with EMC DEE-1421 preparation products which designed to deliver the High value DEE-1421 questions by making you pass the DEE-1421 test at your first time. Try the free DEE-1421 demo right now.

Free DEE-1421 Demo Online For EMC Certifitcation:

NEW QUESTION 1
Which Dell EMC tool allows theauditing of user access and anti-virus scanning on an Isilon cluster?

  • A. Access zones
  • B. InstghtQ
  • C. EMCopy
  • D. CEE

Answer: D

NEW QUESTION 2
A company is planning to replicate a dataset to a newly implement Dell EMC Isilon cluster. SyncIQ will used from the source to the target cluster. The company's system administrator wants to know how long the initial synchronization will take seeding. The administrator provides the following information:
DEE-1421 dumps exhibit Link speed between clusters is 1 Gb/s
DEE-1421 dumps exhibit Link speed efficiency is 85%
DEE-1421 dumps exhibit SynclQ domain sue is 125 TB
If no SynctQ performance rules are set, what is the estimated number of days?

  • A. 10
  • B. 12
  • C. 14
  • D. 16

Answer: A

NEW QUESTION 3
The :”nfs2” file system has been experiencing delays that have been impacting the entire Dell EMC Isilon cluster. Neither Snapshots nor SyncIQ is configured for these directories. Use the “Launch Simulator” button to verify the SSD strategy. Note: It is necessary to ‘close’ (x) the simulator window to answer the question.
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
Based on your findings, which operation should be performed to address the delays?

  • A. None; the 'Use SSDs for metadata read/write acceleration' strategy is set correctly
  • B. None; the 'Use SSDs for metadata read acceleration' strategy is set correctly
  • C. Set the strategy to 'Use SSDs for metadata read acceleration"
  • D. Set the strategy to "Use SSDs for metadata read/write acceleration'

Answer: D

NEW QUESTION 4
A company has an existing Dell EMC 4-node X410 Gen 5 cluster with approximately 100 TB ofSMB shares connectedusing two InfiniBand 8-port switches The company wants a technical refresh of the cluster with a new 4-node H5O0 Gen 6 cluster with two 16-port InrmiBand switches The existing cluster has SynclQ. SmartConnect Advancedand Smart Ports licenses installed
To move me data from the existing nodes to the new nodes, which migration plan is recommended?

  • A. Modify the default tile pool policy to move the dataSwap the existing InfiniBand switches with the new switches
  • B. Setup a new cluster with the new Gen 6 nodes and its InfiniBand switches Use SynclQ to migrate the data and then SmartFail the existing cluster
  • C. Setup a new cluster with the new Gen 8 nodes and the InfiniBand switches Use EMCopy to migrate the data and then use "sharedup" to create the shares
  • D. Add the new nodes to the existing cluster.Modify the default file pool policy to move the data and then SmartFail the existing nodes

Answer: D

NEW QUESTION 5
A media company has a Microsoft Windows-based infrastructure and uses Adobe media editing tools to create advertisements for its customers Users from the Media Production department store all types of media ties on a Dell EMC Isilon cluster.
In addition, users from the Support department are not allowed to store MP3 and AVI files to the NAS system. Both the Media Production and Support departments need to access other common data on the cluster. Due to workflow procedures, the media files are stored on the same path on me Isilon cluster.
The company wants toKnow which ision features are available and can restrict the Support department users from writing certain media file types onto the Isilon cluster. Which recommendation should be provided/

  • A. Create a single SMB share for bothdepartmentsUse the share security settings end Windows NTFS settings to restrict thetypes
  • B. Create an SMG snare for the Support department and restrict the Media Productiondepartment users from accessing the shareCreate another SMB share for Via Media Production department and apply file Altering
  • C. Create a separate Access zone for each departmentUse Sync 10 to replicate the data and exclude the media files
  • D. Create aSMBsnare for me MediaProduction department and restrict the Support department users from accessing the shareCreole another SMB share for the Support department and apply file filtering

Answer: A

NEW QUESTION 6
A company plans to deploy N+2d:1n protection on a 7 node Dell EMC Isilon cluster. How much capacity will be used to store a 1536 KB file?

  • A. 1280 KB
  • B. 1792 KB
  • C. 1920 KB
  • D. 2048 KB

Answer: D

NEW QUESTION 7
The company's IT team is now looking (or a new data protection strategy.The company wants to:
DEE-1421 dumps exhibit Minimize the backup window
DEE-1421 dumps exhibit Increase the speed of data recovery
DEE-1421 dumps exhibit Reduce the network traffic
DEE-1421 dumps exhibit Reduce the overall growth of the backup datasets
The IT team indicates that their current backup hardware will be used in any solution. Which solution meets their requirement?

  • A. Change the backup strategy to token-based backups
  • B. Increase the backup tape block size to 512 KB
  • C. Implement an incremental forever backup strategy
  • D. Configure the DMA to use IPv6 for better performance

Answer: C

NEW QUESTION 8
You have been asked to design a Dell EMC Isilon cluster running OneFS 8.x for a service provider. One of the most critical areas to the provider is data segregation with multi-tenants. Use the “Launch Simulator” button to identify the current condition of the cluster: Note: It is necessary to “close” (x) the simulator window to answer the question.
Based on your findings, what is the cluster’s current condition?
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit

  • A. All non-System Access zones are connected to the same groupne
  • B. each with its own DNS server
  • C. Each non-System Access zone is connected to an individual groupne
  • D. each with its own DNS server
  • E. All non-System Access zones are connected to the same groupnet with the same DNS server
  • F. Each non-System Access zone is connected to an individual groupnet with the same DNS server.

Answer: A

NEW QUESTION 9
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
DEE-1421 dumps exhibit 200 TB of Fibre Channel drives on NetApp ONTAP 7
DEE-1421 dumps exhibit Environment is expected to grow 200 TB over the next three years
In order to remove the encryption key on the SED drives, which steps are required?

  • A. SmartFail the cluster and then remove the drive
  • B. Suspend the cluster and then SmarlFail the drive
  • C. Suspend the node and then remove the drive
  • D. SmartFail and then remove the drive

Answer: C

NEW QUESTION 10
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens.
When displaying a question, you can easily review the related case study by clicking on the “Review Case Study” icon shown below:
DEE-1421 dumps exhibit
Case Study 5– Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes. Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC NetWorker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?

  • A. Add A100 Backup Accelerators and configurefor two-way NDMP
  • B. Change the backup strategy to token-based backups
  • C. Exclude the targets datasets from the backup job
  • D. Create more parallel streams to utilize multi-stream NDMP backups

Answer: A

NEW QUESTION 11
A company is migrating files from a third-party storage platform thatis authenticated through AD. The migration toolbeing used is Dell EMC *EMCOPYexe* running on a separate Microsoft Windows host. In orderto run theEMCopy process and complete themigration, which type of account is required?

  • A. Local useraccount that has members of thelocal Windows Backup Operators group and local Administrationgroup on the source and target
  • B. Local user account that has permission to use thef MCOPV.exe utility on the separate Windows host
  • C. Domain user account created explicitly to use isi_vol_copy or isi_vol_copy_vnx on the source and target
  • D. Domain user account that is a member of the local Windows Backup Operators group on the source and target

Answer: D

NEW QUESTION 12
You are working with a company lo migratefrom a Microsoft Windows file erver to a Dell EMC Isilon cluster using the account 'admin 1" in the 'Domain Admin* group. When opening a directory, you receive an error message stating 'permission denied* You check me permissions and see that Domain Users are denied. Domain Admin has Full Control, and adrmn1has read permission
Why is the access denied?

  • A. Deny ACE entry is listed first
  • B. admin1 is a member of the Domain Admin group
  • C. adrmn1is not the owner of the directory
  • D. admin 1 only has read permission

Answer: D

NEW QUESTION 13
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens.
When displaying a question, you can easily review the related case study by clicking on the “Review Case Study” icon shown below:
DEE-1421 dumps exhibit
Case Study 5– Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes. Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC NetWorker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a new data protection strategy. The company wants to:
DEE-1421 dumps exhibit Minimize the backup window
DEE-1421 dumps exhibit Increase the speed of data recovery
DEE-1421 dumps exhibit Reduce the network traffic
DEE-1421 dumps exhibit Reduce the overall growth of the backup datasets
The IT Team indicates that their currently backup hardware will be used in any solution. Which solution meets their requirements?

  • A. Implement an incremental forever backup strategy
  • B. Configure the DMA to use IPv6 for better performance
  • C. Change the backup strategy to token-based backups
  • D. Increase the backup tape block size to 512 KB

Answer: A

Explanation:
Explanation
SPECILA INSTRUCTIONS:
The reaming Part 1 questions are associated with four studies thatdescribeenvironment or setting. Each case study appears on its display screen. Question for each case study will appear on separate display screens. When display a question, you can easily review the related case study by clicking on the "Review Case Study"
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit

NEW QUESTION 14
Which protocol to send isi diagnostic gather logs from a Dell WEMC lsilon cluster to Dell EMC Support when the ESRP gateway is unable?

  • A. SCP
  • B. FTP
  • C. HTTPS
  • D. FTPS

Answer: B

NEW QUESTION 15
A company implementing Superna Eyeglass to automate and orchestrate SyncIQ failover and failback. What is one of the requirements when Dell EMC isilon duster?

  • A. Administrator account must be used
  • B. System Access zone must be used
  • C. Dedicated subnet must exist
  • D. Dedicated IP pool must exist

Answer: C

NEW QUESTION 16
A Dell EMC Isilon administrator has a 6-node X400 cluster. As the hardware is approaching end of service life, the administrator has planned for a technical refresh by replacing the 6-node X400 cluster with a 4-node H500 cluster.
The new 4-node H500 is added to the existing cluster and a SmartPools trial license is activated for data migration. The default location for the data and snapshots is changed in the default file pool policy from an X400 node pool to a H500 node pool. The SmartPool job is then run manually.
After the SmartPool job is finished, the X400 node pool still consumes approximately 10% of the storage. What is a possible reason for this issue?

  • A. SyncIQ migration method should have been used
  • B. Manually-managed files and directories still exist
  • C. SmartPools mat license is not sufficient, a W license « required
  • D. SmartPool job finished with error
  • E. Dell EMC Support needs to be contacted

Answer: B

NEW QUESTION 17
Acompany has 7 PB of PACS archivedata on their Dell FMC Isilon cluster. The PACS application currently creates and stores large containers of small files. Based on local healthcare regulation changes, the company can no longer use large containers of small files. As a result, the company wants to know if Isilon can support the new regulatory PACS requirement while maximizing the storage capacity for small tiles
Which licensed feature should be activated?

  • A. PACS
  • B. SFSE
  • C. SmartPools
  • D. SmartQuota

Answer: C

NEW QUESTION 18
A company has a Dell EMC Isilon cluster that will be used for a large amount of client requests. SmartConnect has been configured to help load balance the clients across the cluster. How does SmartConnect help the load balancing?

  • A. Dynamically updating changes to DNS
  • B. Caching lookup requests
  • C. Forwarding DNS requests
  • D. Directing the connections to different nodes

Answer: D

NEW QUESTION 19
A Dell EMC Isilon administrator has set up security on a share as shown in the exhibit Users in the group entitled "domain users'* should only be allowed read access to the share.
DEE-1421 dumps exhibit
DEE-1421 dumps exhibit
Which user or group is able to only read from the share called "test"?

  • A. student only
  • B. everyone
  • C. domain users
  • D. root only

Answer: C

NEW QUESTION 20
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens.
When displaying a question, you can easily review the related case study by clicking on the “Review Case Study” icon shown below:
DEE-1421 dumps exhibit
Case Study 5– Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC NetWorker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigation, you notice that the backup job targets two paths. This could be the cause of the lengthy backup times.
What advice should be provided to the team?

  • A. Exclude the largest datasets from the backup job
  • B. Add A100 Backup Accelerators and configure for two-way NDMP
  • C. Create more parallel streams to utilize multi-stream NDMP backups.
  • D. Change the backup strategy to token-based backups.

Answer: C

NEW QUESTION 21
A company wants to purchase four new Dell EMC Isilon H500 nodes to add their current Gen 5 cluster. Which internal requirements are needed?

  • A. Replace the IB switches with Ethernet switches
  • B. Gen 6 nodes cannot be mixed with Gen 5 nodes
  • C. Add two new Ethernet switches in addition to the existing IB switches
  • D. Use the existing IB switches

Answer: C

NEW QUESTION 22
A company has a medical application that generates a large number of media files.The file count is well over one billion and is stored on a Dell EMC lsilon 8-node N14I0 Cluster Currently, each node ft connected to me network using two 10GbE concoctions. The Linux-based application does not require high bandwidth; however, it is latency sensitive. Additionally, the Linux hosts are connected to the cluster over NFSv3 .The application generates approximately 10.000 files every 10 minutesfor the past four years, the cluster has been growing at a rate of one additional node per year. The company is running out free ports on their redundant network switches. They want to know what can be done to ensure continuous availability. They do not want to invest in upgrading the network infrastructure. In addition the company needs to reduce the number ol consumed interface ports on the switches.
Which recommendation should be provided?

  • A. Leave the first four nodes of the cluster connected to both network switches and free up the remanding connections
  • B. Leave the fast 10GbE Interfacefrom each node connected to the same network switch and hoe up the remaining connections
  • C. Leave the first node of the cluster connected to both network switches and free up theremainingconnections
  • D. Leave the fast four nodes of the cluster connected to both network switches with LACP and free up the remaining connections

Answer: D

NEW QUESTION 23
You nave just configured a Dell EMC lsilon cluster. One of the remaining tastes is to enable alert notification. The cluster is on a network segment behind a firewall for security. You have determined which node is the CELOG master and have enabled connectivitybetween it and the ESRS gateway.
Testing shows that alerts were working for several daysbut have suddenly slopped. Which action is required to resolve this issue?

  • A. Edit and enable the Alert Channel for ConnectEMC
  • B. Enable TCP port 443 between all nodes and the ESRS gateway
  • C. Enable TCPport 25 Between all nodes and the SMTP server
  • D. Ensure only the first cluster nodeis in the 'allowed list in Work Channel settings

Answer: A

NEW QUESTION 24
......

Recommend!! Get the Full DEE-1421 dumps in VCE and PDF From Dumps-hub.com, Welcome to Download: https://www.dumps-hub.com/DEE-1421-dumps.html (New 60 Q&As Version)