Master the NS0-520 NetApp Certified Implementation Engineer - SAN. ONTAP content and be ready for exam day success quickly with this Passleader NS0-520 latest exam. We guarantee it!We make it a reality and give you real NS0-520 questions in our Network-Appliance NS0-520 braindumps.Latest 100% VALID Network-Appliance NS0-520 Exam Questions Dumps at below page. You can use our Network-Appliance NS0-520 braindumps and pass your exam.
Online NS0-520 free questions and answers of New Version:
NEW QUESTION 1
As a system administrator, you perform a routine check of available storage space on your FAS2750. You notice that the vol_1 volume is approaching 100% capacity. The volume is configured with the space guarantee set to volume and the LUN reservation is disabled. You want to free up space in the volume without increasing its size.
Which action would accomplish this task?
Answer: C
NEW QUESTION 2
You are setting up FC ports and must configure the speeds for both the SAN and the host ports. In this scenario, which statement is correct?
Answer: B
NEW QUESTION 3
Referring to the exhibit, what is the problem with switch port 0?
Answer: C
NEW QUESTION 4
You are configuring a FAS8300 HA pair running ONTAP 9.8 with two hosts that requires SAN LUNs. The cluster is in a secure data center without switches. In this scenario, which block protocol is supported on the hosts?
Answer: B
Explanation:
Direct-attachment
In a direct-attached configuration, one or more hosts are directly connected to the controllers. You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-193CC377-5C
NEW QUESTION 5
Exhibit.
You are working on a project to install a new AFF A300 storage array. You use a pair of Nexus 3596 switches for FC connectivity between your VMware ESXi servers and the AFF A300.
Which SAN switch feature must be enabled to accomplish this task?
Answer: A
NEW QUESTION 6
You configured a SAN host with a 4-node ONTAP 9.5 cluster that uses default settings. All paths are available from the host to the four nodes. You have a requirement to see only two paths to each LUN. One path is optimized and the other is non-optimized.
In this scenario, which NetApp SAN feature supports this requirement?
Answer: C
NEW QUESTION 7
Exhibit.
The exhibit shows the Inn show command output for the oradata oraFinProd_l LUN. Which two statements ate correct about the LUN'? (Choose two.)
Answer: BD
NEW QUESTION 8
Click the Exhibit button.
You have a 2-node cluster in a single-fabric SAN. Host 1 and Host 2 are part of a VMware cluster and access the same LUNs that reside in your NetApp storage.
Referring to the exhibit, what would be a way to test whether the multipathing is properly configured in your environment?
Answer: B
NEW QUESTION 9
What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?
Answer: A
Explanation:
Reference: https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/GUID-650DC466-CA3F
FCEEB52E7.html (6th bullet)
NEW QUESTION 10
You want to perform online data migration using Foreign LUN Import. In this scenario, which two conditions are required to support this task? (choose two)
Answer: CD
Explanation:
FLI does not support iSCSI connections directly. In order for iSCSI LUNs to be migrated using FLI, the LUN type must be changed to FC. After the migration is complete, the LUN type is changed back to
iSCSI.
You can find more information on this link:
https://docs.netapp.com/us-en/ontap-fli/san-migration/concept_lun_requirements_and_limitations.html
NEW QUESTION 11
You are implementing a new AFF A800 HA pair and are required to migrate NetApp E-Series E2624 data to the AFF A800 controllers. You do not have a host server that is available for the migration.
In this scenario, which NetApp migration method is supported?
Answer: D
NEW QUESTION 12
You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage.
What are three reasons for this problem? (Choose three.)
Answer: ABD
NEW QUESTION 13
Which commands allow you to enable NetApp deduplication and verify space savings?
Answer: A
NEW QUESTION 14
A customer experiences intermittent connectivity problems between an ESXi server and FC LUNs in an SVM. The customer has examined the nodes hosting the LUNs and both the disk and CPU performance are below 50% utilization. The customer examined the switch ports connected to the storage array, and they ate also below 50% utilization.
Which two steps would you perform next in this scenario? (Choose two.)
Answer: CD
NEW QUESTION 15
Which row of items should you look up in the IMT (Interoperability Matrix Tool) when designing a NetApp Storage Solution for a customer?
Answer: C
NEW QUESTION 16
You are testing iSCSI LUN failover across a 4-node FAS9000 fabric-attached MetroCluster configuration.
In this scenario, which front end configuration is required for non-disruptive host LUN failover between sites?
Answer: A