Master the NS0-520 NetApp Certified Implementation Engineer - SAN. ONTAP content and be ready for exam day success quickly with this Passleader NS0-520 latest exam. We guarantee it!We make it a reality and give you real NS0-520 questions in our Network-Appliance NS0-520 braindumps.Latest 100% VALID Network-Appliance NS0-520 Exam Questions Dumps at below page. You can use our Network-Appliance NS0-520 braindumps and pass your exam.

Online NS0-520 free questions and answers of New Version:

NEW QUESTION 1

As a system administrator, you perform a routine check of available storage space on your FAS2750. You notice that the vol_1 volume is approaching 100% capacity. The volume is configured with the space guarantee set to volume and the LUN reservation is disabled. You want to free up space in the volume without increasing its size.
Which action would accomplish this task?

  • A. Increase the size of the LUN.
  • B. Increase the Snapshot Reserve.
  • C. Increase the aggregate size.
  • D. Use deduplication.

Answer: C

NEW QUESTION 2

You are setting up FC ports and must configure the speeds for both the SAN and the host ports. In this scenario, which statement is correct?

  • A. Set the target port speed higher than the switch port speed.
  • B. Set the target port speed to auto-negotiation.
  • C. Set the target port speed to match the switch port speed.
  • D. Set the target port speed lower than the switch port speed.

Answer: B

NEW QUESTION 3

NS0-520 dumps exhibit
NS0-520 dumps exhibit
Referring to the exhibit, what is the problem with switch port 0?

  • A. The transmit and receive links were switched.
  • B. The SFP+ is faulty.
  • C. The receive power is lower.
  • D. The link is not connected.

Answer: C

NEW QUESTION 4

You are configuring a FAS8300 HA pair running ONTAP 9.8 with two hosts that requires SAN LUNs. The cluster is in a secure data center without switches. In this scenario, which block protocol is supported on the hosts?

  • A. FCP
  • B. ISCSI
  • C. FCoE
  • D. NVMe

Answer: B

Explanation:
Direct-attachment
In a direct-attached configuration, one or more hosts are directly connected to the controllers. You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-193CC377-5C

NEW QUESTION 5

Exhibit.
NS0-520 dumps exhibit
You are working on a project to install a new AFF A300 storage array. You use a pair of Nexus 3596 switches for FC connectivity between your VMware ESXi servers and the AFF A300.
Which SAN switch feature must be enabled to accomplish this task?

  • A. N_Port ID visualization (NP1V)
  • B. Open Shortest Path First (OSPF)
  • C. Link Aggregation Control Protocol (LACP)
  • D. N_Port Visualization (NPV)

Answer: A

NEW QUESTION 6

NS0-520 dumps exhibit
You configured a SAN host with a 4-node ONTAP 9.5 cluster that uses default settings. All paths are available from the host to the four nodes. You have a requirement to see only two paths to each LUN. One path is optimized and the other is non-optimized.
In this scenario, which NetApp SAN feature supports this requirement?

  • A. portsets
  • B. SLM
  • C. VLANs
  • D. igroups

Answer: C

NEW QUESTION 7

Exhibit.
NS0-520 dumps exhibit
The exhibit shows the Inn show command output for the oradata oraFinProd_l LUN. Which two statements ate correct about the LUN'? (Choose two.)

  • A. The LUN Is thick provisioned.
  • B. The LUN supports SCSI Tin unmap.
  • C. The LUN type is Windows.
  • D. The LUN is thin provisioned.

Answer: BD

NEW QUESTION 8

Click the Exhibit button.
NS0-520 dumps exhibit
You have a 2-node cluster in a single-fabric SAN. Host 1 and Host 2 are part of a VMware cluster and access the same LUNs that reside in your NetApp storage.
Referring to the exhibit, what would be a way to test whether the multipathing is properly configured in your environment?

  • A. Verify whether all destination storage target ports are contained in the same zone as Host 1.
  • B. Administratively set ports 0a and 0c on Controller 1 to the offline setting.
  • C. Power off the SAN switch.
  • D. Disconnect Host 1 port and verify whether Host 2 is still able to run the VMs.

Answer: B

NEW QUESTION 9

What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?

  • A. 8
  • B. 12
  • C. 16
  • D. 4

Answer: A

Explanation:
Reference: https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/GUID-650DC466-CA3F
FCEEB52E7.html (6th bullet)

NEW QUESTION 10

You want to perform online data migration using Foreign LUN Import. In this scenario, which two conditions are required to support this task? (choose two)

  • A. ISCSI protocol LIFs must be added to the data SVM
  • B. ISCSI targets must be added to the ONTAP ISCSI initiator
  • C. FCP protocol LIFs must be added to the data SVM
  • D. FCP initiator ports must be available

Answer: CD

Explanation:
FLI does not support iSCSI connections directly. In order for iSCSI LUNs to be migrated using FLI, the LUN type must be changed to FC. After the migration is complete, the LUN type is changed back to
iSCSI.
You can find more information on this link:
https://docs.netapp.com/us-en/ontap-fli/san-migration/concept_lun_requirements_and_limitations.html

NEW QUESTION 11

You are implementing a new AFF A800 HA pair and are required to migrate NetApp E-Series E2624 data to the AFF A800 controllers. You do not have a host server that is available for the migration.
In this scenario, which NetApp migration method is supported?

  • A. OnCommand Unified Manager (OCUM)
  • B. NetApp Data Availability Services (NDAS)
  • C. SnapMirror Synchronous (SM-S)
  • D. Foreign LUN Import (FLI)

Answer: D

NEW QUESTION 12

You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage.
What are three reasons for this problem? (Choose three.)

  • A. The protocol has not been enabled on the NetApp cluster.
  • B. You need to add the IQN of the Windows host to the newly created LUN.
  • C. The IQN of the Windows host is not included in the igroup for the new LUN.
  • D. The wrong igroup has been associated with the new LUN.
  • E. The volume has not been enabled for iSCSI access.

Answer: ABD

NEW QUESTION 13

Which commands allow you to enable NetApp deduplication and verify space savings?

  • A. sis on <vol>, sis start <vol>, df s <vol>
  • B. asis on <vol>, asis start <vol>, df s <vol>
  • C. sis on <vol>, sis start <vol>, df r <vol>
  • D. sis on, sis start, df p <vol>

Answer: A

NEW QUESTION 14

A customer experiences intermittent connectivity problems between an ESXi server and FC LUNs in an SVM. The customer has examined the nodes hosting the LUNs and both the disk and CPU performance are below 50% utilization. The customer examined the switch ports connected to the storage array, and they ate also below 50% utilization.
Which two steps would you perform next in this scenario? (Choose two.)

  • A. Verify that the host is using SnapDrive.
  • B. Verify that the host Ethernet interfaces are using jumbo frames.
  • C. Verify that the host recommended settings were applied by Virtual Storage Console.
  • D. Verify that the HBA queue depth is set properly.

Answer: CD

NEW QUESTION 15

Which row of items should you look up in the IMT (Interoperability Matrix Tool) when designing a NetApp Storage Solution for a customer?

  • A. Host OS & patches, FC WWPN, Volume Manager, File System version
  • B. Host OS, iSCSI IQN, Volume Manager, Clustering
  • C. Host OS & patches, HBA driver, Volume Manager, File System, Clustering
  • D. Host OS, HBA driver, Host Memory & CPU Speed, File System, Clustering

Answer: C

NEW QUESTION 16

You are testing iSCSI LUN failover across a 4-node FAS9000 fabric-attached MetroCluster configuration.
In this scenario, which front end configuration is required for non-disruptive host LUN failover between sites?

  • A. an intercluster LIF
  • B. a stretched Layer 2 network
  • C. Ipv6
  • D. a stretched VSAN

Answer: A

NEW QUESTION 17
......

Thanks for reading the newest NS0-520 exam dumps! We recommend you to try the PREMIUM Downloadfreepdf.net NS0-520 dumps in VCE and PDF here: https://www.downloadfreepdf.net/NS0-520-pdf-download.html (234 Q&As Dumps)